Lot B7498 is one of 3 lots of Liraglutide we have release-tested for this catalogue, scored on purity, quantity, and batch traceability. Independent third-party HPLC/MS verification of this lot is available on request.
9.8/10
A+ Excellent
Purity
3.8 / 4
Quantity
4.0 / 4
Identifier
2.0 / 2
The test score is calculated from purity (how much of the vial content is the expected compound, with values closest to 100% best and below 98% considered unacceptable), quantity (how close the measured amount is to the label claim, more than plus or minus 20% is unacceptable), and identifier (whether the batch this vial came from can be traced to a certificate).
Sample details
ProductLiraglutide 5mg
Sample typeSealed retail vial
Date received05 Jun 2026
Physical detailsPrinted label / aluminium crimp / amber cap
Test details
MethodRP-HPLC-UV + LC-MS
Tested on07 Jun 2026
Tested byRTT Peptides QC
ReportQC-23827
Score breakdown
Purity
99.71%
3.8 / 4
Measured purity by RP-HPLC-UV against the ≥ 98.0% release specification. Net peptide content 93.5%.
Quantity
4.9mg
4.0 / 4
Label claim 5mg, measured 4.9mg, divergence -2.0%. Within plus or minus 5% of label scores full marks.
Identifier
B7498
2.0 / 2
Batch identifier printed on the vial and traceable to this certificate, so the lot can be verified end to end.
Analytical release certificate · RP-HPLC-UV with LC-MS confirmation Independent third-party verification available on request.
ReportQC-23827Issued2026-06-08Page1 of 1
Certificate of Analysis
Liraglutide · Lot B7498
SampleLiraglutide
Issued forRTT Peptides
Lot / BatchB7498
Label claim5mg
CASN/A
AppearanceWhite lyophilised powder
Date received2026-06-05
Date analysed2026-06-07
01 Purity by RP-HPLC-UV
Figure 1 · Reverse-phase HPLC-UV chromatogram at 214 nm. C18, 2.7 µm; gradient 0.1% TFA in water / acetonitrile at 1.0 mL/min.
Purity by RP-HPLC-UV: component retention time, peak area, and area percent
#
Component
RT (min)
Area (mAU·s)
Area %
1
RRT 0.68
6.14
2.5
0.06
2
Liraglutide ▸ main
8.99
4187.8
99.71
3
RRT 1.36
12.24
5.9
0.14
4
RRT 1.41
12.67
3.8
0.09
✓
Purity (HPLC) 99.71% · net peptide content 93.5% · meets the ≥ 98.0% release specification.
02 Identity by LC-MS
Expected average massper structure
Observed massconsistent
✓
Identity confirmed · observed mass conforms to the expected structure of Liraglutide.
03 Summary of results
Summary of results: test, method, specification, result, and outcome
Test
Method
Specification
Result
Outcome
Purity
RP-HPLC-UV, 214 nm
≥ 98.0 %
99.71 %
✓ Pass
Identity
LC-MS (ESI+)
Consistent with structure
Confirmed
✓ Pass
Net peptide content
By difference
Report
93.5 %
n/a
Appearance
Visual
White lyophilised powder
Conforms
✓ Pass
Reconstitution
Bacteriostatic water
Clear, particulate-free
Conforms
✓ Pass
The submitted lot conforms to identity and meets the stated purity specification. Analysis was performed by RP-HPLC-UV with LC-MS confirmation. Results relate only to the lot as received and tested and do not constitute a certificate of any third party.
Quality Assurance · RTT Peptides
Issued under the RTT Peptides quality programme; this is the vendor's own release certificate. Independent third-party HPLC/MS verification of any lot is available on request. Products are supplied strictly as research reagents for in-vitro laboratory use only, not for human or animal consumption. Report QC-23827 · RP.
This is the vendor's own release certificate. Independent third-party HPLC/MS verification of this lot is available on request.
Research use only
RTT Peptides sells laboratory research reagents. They are not for human or animal consumption. Please confirm before entering.